Wind tunnel measurements of indoor air quality in a building with natural cross-ventilation

Díaz-Calderón, S. F.; Gromke, C.; Castillo, J. A.; Huelsz Lesbros, Guadalupe

Facultad de Ciencias, UNAM, publicado en Revista Mexicana de Física y cosechado de y cosechado de Revistas UNAM

Licencia de uso

La titularidad de los derechos patrimoniales de esta obra pertenece a las instituciones editoras. Su uso se rige por una licencia Creative Commons BY-NC-ND 4.0 Internacional, https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.es, para un uso diferente consultar al responsable jurídico del repositorio por medio del correo electrónico rmf@ciencias.unam.mx. Ver términos de la licencia

Procedencia del contenido

Entidad o dependencia
Facultad de Ciencias, UNAM
Revista
Repositorio
Contacto
Revistas UNAM. Dirección General de Publicaciones y Fomento Editorial, UNAM en revistas@unam.mx

Cita

Díaz-Calderón, S. F., et al. (2025). Wind tunnel measurements of indoor air quality in a building with natural cross-ventilation. Revista Mexicana de Física; Vol. 71 Núm. 1 Jan-Feb, 2025. Recuperado de https://repositorio.unam.mx/contenidos/4161184

Descripción del recurso

Autor(es)
Díaz-Calderón, S. F.; Gromke, C.; Castillo, J. A.; Huelsz Lesbros, Guadalupe
Tipo
Artículo de Investigación
Área del conocimiento
Físico Matemáticas y Ciencias de la Tierra
Título
Wind tunnel measurements of indoor air quality in a building with natural cross-ventilation
Fecha
2025-01-01
Resumen
In recent years, there has been an increase in indoor air quality studies in buildings, which examine minimum requirements to reduce the probability of respiratory disease transmission. These studies are primarily conducted in existing buildings, with fewer evaluations of generic geometry buildings in wind tunnels. These experimental studies are valuable, among other things, for validating numerical models of Computational Fluid Dynamics (CFD). This study employs the experimental technique of electron capture detection to obtain the distribution of a tracer gas throughout the interior volume of a scaled building with cross-ventilation in a modelled atmospheric boundary layer flow. The building is considered isolated (without neighbors) and features windows at the same bottom height of the windward and leeward facades. A facade porosity (the ratio of area between the window and the facade) of 10% is considered. Maintaining geometric and dynamic similarity, the results are scaled based on a building height of 2.8 m and an incident wind velocity at the building height of 0.85 m/s. Under these conditions, the values of air exchange rate I = 0.0167 s −1 , nominal time τn = 60 s, and 60 air changes per hour (ACH) are calculated. It is anticipated that the concentration results presented in this study will be utilized in future validations of CFD models.
Tema
Natural ventilation; indoor air quality; wind tunnel measurements; tracer gas; electron capture detection