dor_id: 23332

506.#.#.a: Público

590.#.#.d: Los artículos enviados a la Revista Internacional de Contaminación Ambiental se juzgan por medio de un proceso de revisión por pares

510.0.#.a: Consejo Nacional de Ciencia y Tecnología (CONACyT), Sistema Regional de Información en Línea para Revistas Científicas de América Latina, el Caribe, España y Portugal (Latindex), Scientific Electronic Library Online (SciELO), SCOPUS, Web Of Science (WoS), Aquatic Sciences and Fisheries Abstracts, Cab Abstracts, Cab Health, Chemical Abstracts, Elsevier Biobase, Elsevier Geo Abstracts, Periódica, Pollution Abstracts, SCOPUS, Water Resources Abstracts

561.#.#.u: https://www.atmosfera.unam.mx/

650.#.4.x: Biología y Química

336.#.#.b: article

336.#.#.3: Artículo de Investigación

336.#.#.a: Artículo

351.#.#.6: https://www.revistascca.unam.mx/rica/index.php/rica/index

351.#.#.b: Revista Internacional de Contaminación Ambiental

351.#.#.a: Artículos

harvesting_group: RevistasUNAM

270.1.#.p: Revistas UNAM. Dirección General de Publicaciones y Fomento Editorial, UNAM en revistas@unam.mx

590.#.#.c: Open Journal Systems (OJS)

270.#.#.d: MX

270.1.#.d: México

590.#.#.b: Concentrador

883.#.#.u: http://www.revistas.unam.mx/front/

883.#.#.a: Revistas UNAM

590.#.#.a: Coordinación de Difusión Cultural, UNAM

883.#.#.1: https://www.publicaciones.unam.mx/

883.#.#.q: Dirección General de Publicaciones y Fomento Editorial, UNAM

850.#.#.a: Universidad Nacional Autónoma de México

856.4.0.u: https://www.revistascca.unam.mx/rica/index.php/rica/article/view/32828/30113

100.1.#.a: Gaytan, Martha; Castro, Teresa; Bonilla, Patricia; Lugo, Alfonso; Vilaclara, Gloria

524.#.#.a: Gaytan, Martha, et al. (1997). Estudio preliminar de muestras seleccionadas de agua potable en la ciudad de México. Revista Internacional de Contaminación Ambiental; Vol. 13, Núm. 2, 1997; 73-78. Recuperado de https://repositorio.unam.mx/contenidos/23332

245.1.0.a: Estudio preliminar de muestras seleccionadas de agua potable en la ciudad de México

502.#.#.c: Universidad Nacional Autónoma de México

561.1.#.a: Centro de Ciencias de la Atmósfera, UNAM

264.#.0.c: 1997

264.#.1.c: 2012-08-22

653.#.#.a: Drinking water, bacteriological pollution, physicochemical quality, indicator bacteria

506.1.#.a: La titularidad de los derechos patrimoniales de esta obra pertenece a las instituciones editoras. Su uso se rige por una licencia Creative Commons BY-NC 4.0 Internacional, https://creativecommons.org/licenses/by-nc/4.0/legalcode.es, fecha de asignación de la licencia 2012-08-22, para un uso diferente consultar al responsable jurídico del repositorio por medio del correo electrónico claudio.amescua@atmosfera.unam.mx

884.#.#.k: https://www.revistascca.unam.mx/rica/index.php/rica/article/view/32828

001.#.#.#: oai:ojs.phoenicis.tic.unam.mx:article/32828

041.#.7.h: spa

520.3.#.a: La Ciudad de México es un ejemplo crítico de los problemas de abasto de agua potable y contaminación, debido a su población de 19 millones habitando una cuenca cerrada, localizada a 2300 msnrn. La creciente urbanización ha disminuído la tasa de recarga del acuífero que la provee del recurso. Un gran volumen de agua debe ser traído de zonas más bajas y distantes, con el consecuente incremento de los costos energéticos yecológicos. Para generar datos acerca del agua potable en puntos seleccionados de la ciudad, se muestrearon 63 localidades de abril a diciembre de 1989 (209 muestras en total). Cuando fue posible, se tomaron muestras de la red municipal, cisternas, tanques y llaves de cocina.Por lo menos se muestreó un lugar en 24 de los 27 Distritos Municipales en la ciudad. Los parámetros fisicoquímicos medidos fueron: temperatura, pH, alcalinidad, dureza, cloruros, sulfatos, sílice, sólidos suspendidos, sólidos totales y conductividad (K25). Los análisis biológicos fueron: coliformestotales, fecales y estreptococos fecales. Con base en un análisis de componentes principales, los datos fueron ordenados en seis grupos de calidad de agua. La calidad del agua para beber en las tomas de la red municipal fue buena en el 53% de los casos, aunque se detectó contaminación cuando e lagua fue distribuida por carros-pipa, cuando provino de pozos locales en el Estado de Mexico o cuando presentó un alto contenido de sólidos suspendidos. El agua para beber tuvo mayor contaminación en las muestras tomadas dentro de las viviendas debido al manejo incorrecto de la mism. México City is a critical example of drinking water supply and pollution, due to its population of nineteen million within a closed basin, 2300 m above sea level. The increasing urbanization has diminished the rate of aquifer reload, and a large amount of water is brought from lower and more distant zones, with increased energetic and ecological costs. To obtain data about drinking water at selected points in the city, 63 locations were sampled from April to December in 1989 (209 total samples). Where available, samples were taken from municipal network intakes, cisterns, roof tanks and kitchen tap water. At least one location was tested in 24 of the 27 Municipal Districts in the city. Measured physico-chemical parameters were: temperature, pH, alkalinity, hardness, chloride, sulfate, silica, total solids, suspended solids and conductivity (K25). Biological analysis were total and faecal coliforms, and faecal streptococci. Based on principal component analysis ordination, data were arranged into six groups of water quality. Drinking water quality at the municipal network intakes was good in 53% of the cases, although pollution was detected when water was distributed by tank trucks, when it came from local wells in-the State of México, or when water had a high suspended solids content. Drinking water was often polluted inside the houses due to poor domestic handling.

773.1.#.t: Revista Internacional de Contaminación Ambiental; Vol. 13, Núm. 2 (1997); 73-78

773.1.#.o: https://www.revistascca.unam.mx/rica/index.php/rica/index

046.#.#.j: 2021-10-20 00:00:00.000000

020.#.#.a: ART||||||||||||||

022.#.#.a: ISSN impreso: 0188-4999

310.#.#.a: Trimestral

300.#.#.a: Páginas: 73-78

264.#.1.b: Centro de Ciencias de la Atmósfera, UNAM

758.#.#.1: https://www.revistascca.unam.mx/rica/index.php/rica/index

handle: 082c0f4005130f75

harvesting_date: 2019-02-06 00:00:00.0

856.#.0.q: application/pdf

245.1.0.b: Preliminary study of selected drinking water samples in México city

last_modified: 2021-11-09 13:10:00

license_url: https://creativecommons.org/licenses/by-nc/4.0/legalcode.es

license_type: by-nc

_deleted_conflicts: 2-8f84b2769e954140eacd1485d1034265

No entro en nada

No entro en nada 2

Artículo

Estudio preliminar de muestras seleccionadas de agua potable en la ciudad de México

Gaytan, Martha; Castro, Teresa; Bonilla, Patricia; Lugo, Alfonso; Vilaclara, Gloria

Centro de Ciencias de la Atmósfera, UNAM, publicado en Revista Internacional de Contaminación Ambiental, y cosechado de Revistas UNAM

Licencia de uso

Procedencia del contenido

Cita

Gaytan, Martha, et al. (1997). Estudio preliminar de muestras seleccionadas de agua potable en la ciudad de México. Revista Internacional de Contaminación Ambiental; Vol. 13, Núm. 2, 1997; 73-78. Recuperado de https://repositorio.unam.mx/contenidos/23332

Descripción del recurso

Autor(es)
Gaytan, Martha; Castro, Teresa; Bonilla, Patricia; Lugo, Alfonso; Vilaclara, Gloria
Tipo
Artículo de Investigación
Área del conocimiento
Biología y Química
Título
Estudio preliminar de muestras seleccionadas de agua potable en la ciudad de México
Fecha
2012-08-22
Resumen
La Ciudad de México es un ejemplo crítico de los problemas de abasto de agua potable y contaminación, debido a su población de 19 millones habitando una cuenca cerrada, localizada a 2300 msnrn. La creciente urbanización ha disminuído la tasa de recarga del acuífero que la provee del recurso. Un gran volumen de agua debe ser traído de zonas más bajas y distantes, con el consecuente incremento de los costos energéticos yecológicos. Para generar datos acerca del agua potable en puntos seleccionados de la ciudad, se muestrearon 63 localidades de abril a diciembre de 1989 (209 muestras en total). Cuando fue posible, se tomaron muestras de la red municipal, cisternas, tanques y llaves de cocina.Por lo menos se muestreó un lugar en 24 de los 27 Distritos Municipales en la ciudad. Los parámetros fisicoquímicos medidos fueron: temperatura, pH, alcalinidad, dureza, cloruros, sulfatos, sílice, sólidos suspendidos, sólidos totales y conductividad (K25). Los análisis biológicos fueron: coliformestotales, fecales y estreptococos fecales. Con base en un análisis de componentes principales, los datos fueron ordenados en seis grupos de calidad de agua. La calidad del agua para beber en las tomas de la red municipal fue buena en el 53% de los casos, aunque se detectó contaminación cuando e lagua fue distribuida por carros-pipa, cuando provino de pozos locales en el Estado de Mexico o cuando presentó un alto contenido de sólidos suspendidos. El agua para beber tuvo mayor contaminación en las muestras tomadas dentro de las viviendas debido al manejo incorrecto de la mism. México City is a critical example of drinking water supply and pollution, due to its population of nineteen million within a closed basin, 2300 m above sea level. The increasing urbanization has diminished the rate of aquifer reload, and a large amount of water is brought from lower and more distant zones, with increased energetic and ecological costs. To obtain data about drinking water at selected points in the city, 63 locations were sampled from April to December in 1989 (209 total samples). Where available, samples were taken from municipal network intakes, cisterns, roof tanks and kitchen tap water. At least one location was tested in 24 of the 27 Municipal Districts in the city. Measured physico-chemical parameters were: temperature, pH, alkalinity, hardness, chloride, sulfate, silica, total solids, suspended solids and conductivity (K25). Biological analysis were total and faecal coliforms, and faecal streptococci. Based on principal component analysis ordination, data were arranged into six groups of water quality. Drinking water quality at the municipal network intakes was good in 53% of the cases, although pollution was detected when water was distributed by tank trucks, when it came from local wells in-the State of México, or when water had a high suspended solids content. Drinking water was often polluted inside the houses due to poor domestic handling.
Tema
Drinking water, bacteriological pollution, physicochemical quality, indicator bacteria
Idioma
spa
ISSN
ISSN impreso: 0188-4999

Enlaces