dor_id: 4161354
506.#.#.a: Público
590.#.#.d: Los artículos enviados a la "Revista Odontológica Mexicana", se juzgan por medio de un proceso de revisión por pares
510.0.#.a: Consejo Nacional de Ciencia y Tecnología (CONACyT); Sistema Regional de Información en Línea para Revistas Científicas de América Latina, el Caribe, España y Portugal (Latindex); Scientific Electronic Library Online (SciELO)
561.#.#.u: http://www.odonto.unam.mx/
650.#.4.x: Medicina y Ciencias de la Salud
336.#.#.b: article
336.#.#.3: Artículo Técnico-Profesional
336.#.#.a: Artículo
351.#.#.6: https://www.revistas.unam.mx/index.php/rom/index
351.#.#.b: Revista Odontológica Mexicana
351.#.#.a: Artículos
harvesting_group: RevistasUNAM.123
270.1.#.p: Revistas UNAM. Dirección General de Publicaciones y Fomento Editorial, UNAM en revistas@unam.mx
590.#.#.c: Open Journal Systems (OJS)
270.#.#.d: MX
270.1.#.d: México
590.#.#.b: Concentrador
883.#.#.u: https://revistas.unam.mx/catalogo/
883.#.#.a: Revistas UNAM
590.#.#.a: Coordinación de Difusión Cultural
883.#.#.1: https://www.publicaciones.unam.mx/
883.#.#.q: Dirección General de Publicaciones y Fomento Editorial
850.#.#.a: Universidad Nacional Autónoma de México
856.4.0.u: https://www.revistas.unam.mx/index.php/rom/article/view/83577/79121
100.1.#.a: Rodríguez-Chávez, Jacqueline Adelina; Flores-Ledesma, Abigailt; Fierro-Ruelas, Geovany; Vargas-Santana, Francisco; Flores-Ruiz, Hugo M; Magaña-Curiel, Karina; Curiel-González, Ricardo
524.#.#.a: Rodríguez-Chávez, Jacqueline Adelina, et al. (2023). Comparación de la profundidad de curado a tres distancias de luz emitida por diodos (LED) con tres colores de resina compuesta. Revista Odontológica Mexicana Órgano Oficial de la Facultad de Odontología UNAM; Vol. 27 Núm. 2, 2023. Recuperado de https://repositorio.unam.mx/contenidos/4161354
245.1.0.a: Comparación de la profundidad de curado a tres distancias de luz emitida por diodos (LED) con tres colores de resina compuesta
502.#.#.c: Universidad Nacional Autónoma de México
561.1.#.a: Facultad de Odontología, UNAM
264.#.0.c: 2023
264.#.1.c: 2024-11-11
653.#.#.a: Profundidad de curado; resina; distancia de polimerización; Norma UNE-EN ISO 4049; depth of cure; resin; cure distance; UNE-EN-ISO Standard 4049-2019
506.1.#.a: La titularidad de los derechos patrimoniales de esta obra pertenece a las instituciones editoras. Su uso se rige por una licencia Creative Commons BY-NC-ND 4.0 Internacional, https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.es, para un uso diferente consultar al responsable jurídico del repositorio por medio del correo electrónico revodontologicamexicana@gmail.com
884.#.#.k: https://www.revistas.unam.mx/index.php/rom/article/view/83577
001.#.#.#: 123.oai:ojs.pkp.sfu.ca:article/83577
041.#.7.h: spa
520.3.#.a: Introduction: If the resin does not receive enough photons at the appropriate wavelengths, the degree of polymerization will be inadequate. There may be greater wear and microleakage, less hardness, and decreased elastic modulus, which can cause pigmentation, postoperative sensitivity, and caries recurrence. Objective: To compare the depth of cure (dc) of the composite resin in shades A1, A2, and A3 at 0 mm, 5 mm, and 10 mm distance with light emitted by diodes (led). Materials and methods: 180 samples in 9 groups (n=20). BrilliantTM NG, Coltene composite resin was used. A1, A2, and A3 at 0 mm (control group), 5 mm, and 10 mm distance of light curing with led lamp (3M Elipar Deep Cure) for 20 s according to the manufacturer"s instructions. Following the test method of the une-en-iso 4049-2019 standard, the non-polymerized material was removed with a plastic spatula. dc (mm) was obtained with a micrometer with an accuracy of ±0.1mm. Results: The depth of cure at a distance of 0 mm of the A1 composite was greater (2.89 mm) compared to the A2 and A3 groups with 2.86 and 2.83 mm respectively, (anova p<0.001). At a distance of 5 mm, the dc of the composite resin A1 was 2.77mm, while with shade A2 it was 2.47mm and A3 was 2.37mm (anova p<0.001. At a distance of 10 mm, the resin A1 obtained a PC of 2.65mm compared to 2.37mm in A2 and 2.23mm in A3 (anova p<0.001). Conclusions: As the distance between the light source and the resin increases, the dc is affected. Therefore, inadvertently moving the light source away from the composite negatively affects curing, reducing the quality and longevity of the material in the mouth.
773.1.#.t: Revista Odontológica Mexicana Órgano Oficial de la Facultad de Odontología UNAM; Vol. 27 Núm. 2 (2023)
773.1.#.o: https://www.revistas.unam.mx/index.php/rom/index
022.#.#.a: ISSN: 1870-199X
310.#.#.a: Trimestral
599.#.#.a: 123
264.#.1.b: Facultad de Odontología, UNAM
doi: https://doi.org/10.22201/fo.1870199xp.2023.27.2.83577
harvesting_date: 2025-01-07 00:00:00.0
856.#.0.q: application/pdf
file_creation_date: 2024-12-04 21:24:20.0
file_modification_date: 2024-12-04 15:24:21.0
file_name: 36ae8e118036239ca03ea8a33dad467d2595207f7b5b5460f3abf80de60170f3.pdf
file_pages_number: 8
file_format_version: application/pdf; version=1.4
file_size: 1288344
245.1.0.b: Comparison of Depth of Cure at Three LED Light Distances with Three Colors of Composite Resin
last_modified: 2025-01-07 00:00:00
license_url: https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.es
license_type: by-nc-nd
No entro en nada
No entro en nada 2